AC/DC Wall Mounted Power Adapter:ADA360K090S001A

Features:

● Wide input voltage: the input working voltage range is 100-240VAC.

● Low power consumption: No-load <0.075W.

● High Energy Efficiency: Six levels of energy consumption, power efficiency up to 88%.

● High reliability: Comply with EN60601-1 CLASS Ⅱ safety level and 2×MOPP insulation protection level, and pass CE.

● Flame retardant insulation:UL94V-0 flame retardant heat resistant material.

● Protection types: short circuit protection, over current protection, over voltage protection, and self-recovery.

● Convenient conversion: Adapt to five conversion plugs of British, Australian, European, American, and Chinese.

 

 

 


Specification

Product Tags

Poduct Detail

图片2

图片1
电源
Input parameter
Voltage Range 100~240 VAC
Frequency Range 47~63Hz
Input Current (Max.) 0.8A @ 115VAC,0.5A @ 230VAC
Efficiency (Typ.) 88%
Standby Consumption 0.1W
Impulse Current (Typ.) 30A @ 115VAC,40A @ 230VAC
Leakage Current (Typ.) 0.1mA @ 264VAC, 60Hz
Output parameters
Output Voltage 9VDC
Voltage Tolerance ±5%
Output Current 4000mA
Rated Power (Max.) 36W
Line Regulation ±1% at full load
Max. Capacitive Load 7000uF
Load Regulation ±1%
Ripple & Noise 50mV (Typ.), 100mV (Max.)@20MHz
Frequency (Typ.) 65kHz
Hold up Time (Typ.) 15mS @ 100VAC

80mS @ 230VAC

Environment
Operating Temperature -40 ~ +70℃
Storage Temperature -40 ~ +85℃
Storage Humidity 95%RH (Max.)
Power Derating 2.7%/℃ @ -40 ~ -25℃

2.4%/℃ @ +50 ~ +70℃,12VDC

2.7%/℃ @ +55 ~ +70℃

Temperature Coefficient ±0.02%/℃
Soldering Temperature 260±5℃ @ Wave Soldering, 5~10s

360±10℃ @ Manual Soldering, 3-5s

Protection Function
Short Circuit Long term short circuit, auto recovery.
Over Current ≥140%IO auto recovery
Over Voltage ≤22VDC @ 9V output
IEC Safety Class CLASSII
Electric Shock Protection 2×MOPP @ primary to secondary
Reliability
MTBF ≥300000H @ 25℃
Safety Standards / Directives
Medical safety EN60601-1
CE Compliant
Isolation Voltage (Min.) Input to Output 4000VAC @ 1 minute test and the leakage current is smaller than 5mA.
EMC
EMI

 

 

 

 

Parameter Standard Test Level / Note
Conducted emission EN55011(CISPR11)/EN55032(CISPR32) CLASS B
Radiated emission EN55011(CISPR11)/EN55032(CISPR32) CLASS B
Voltage flicker EN61000-3-2 -
Harmonic current EN61000-3-2 -
EMS

 

 

 

 

 

 

Parameter Standard Test Level / Note
Electrostatic Discharge IEC/EN61000-4-2 ±8KV/Contact

±15KV/Air

Radiate Susceptibility IEC/EN61000-4-3 10V/m
Electrical Fast Transient burst IEC/EN61000-4-4 ±2 KV
Surge IEC/EN61000-4-5 ±1 KV

Professional/Family medicine

Conducted Susceptibility IEC/EN61000-4-6 10Vr.m.s
Voltage Dips and Interruption IEC/EN61000-4-11 0%,70%
Mechanical Specification
Dimension 70*47*48mm
Enclosure Material Black flame retardant and heat resistant plastics(UL94V-0)
Cooling mode Natural air cooling
Power cable specifications ul2464 × 22Awg * 1m, 5.5 * 2.5 straight head + magnetic ring + SR

 

Application