Universal Travel Adapter 100-220V to 15W 5V Voltage Converter Power Adapter Cord Model: ADA150K050S001A

Features
● Wide input voltage: The input working voltage range is 100-240VAC.
● Low power consumption: No-load <0.075W.
● High energy efficiency: Six levels of energy consumption, power efficiency up to 82%.
● Flame retardant insulation: UL94V-0 flame retardant heat resistant material.
● Protection types: Short circuit protection, over current protection, over voltage protection, and self-recovery.
● Convenient conversion: Adapt to five conversion plugs of British, Australian, European, American, and Chinese.

Specification

Product Tags

Poduct Detail

图片2

图片1
Specifications

Input Parameter

Voltage Range 100~240 VAC
Frequency Range 50~60Hz
Input Current (Max.) 0.14A @ 230VAC
Efficiency (Typ.) 82%
Standby Consumption 0.075W
Impulse Current (Typ.) 30A @ 100VAC,50A @ 240VAC
Leakage Current (Typ.) 0.6mA @ 264VAC, 60Hz

Output Parameter

Output Voltage 5VDC
Voltage Tolerance ±5%
Output Current 3000mA
Rated Power (Max.) 15W
Line Regulation ±3% at full load
Max. Capacitive Load 6000uF
Load Regulation ±3%
Ripple & Noise 50mV (Max.) @20MHz,230V
Frequency (Typ.) 65kHz
Hold Up Time (Typ.) 50mS @ 100VAC80mS @ 240VAC

Environment

Operating Temperature -40 ~ +70℃
Storage Temperature -40 ~ +85℃
Storage Humidity 95%RH (Max.)
Power Derating 3.6%/℃ @ -40 ~ -25℃2.4%/℃ @ +50 ~ +70℃,5VDC2.7%/℃ @ +55 ~ +70℃
Temperature Coefficient ±0.02%/℃
Soldering Temperature 260±5℃ @ Wave Soldering, 5~10s360±10℃ @ Manual Soldering, 3-5s
Protection Function
Short Circuit Long term short circuit, auto recovery.
Over Current ≥120%IO auto recovery
Over Voltage ≤7.5VDC @ 5V output

Reliability

MTBF ≥300000H @ 25℃

Safety Standards / Directives

Medical Safety EN60601-1
CE Compliant
Isolation Voltage (Min.) Input to Output 4000VAC @ 1 minute test and the leakage current is smaller than 5mA.

EMC

EMI Parameter Standard Test Level / Note
Conducted emission EN55011(CISPR11) /EN55032(CISPR32) CLASS B
Radiated emission EN55011(CISPR11) / EN55032(CISPR32) CLASS B
Voltage flicker EN61000-3-2 -
Harmonic current EN61000-3-2 -
EMS Parameter Standard Test Level / Note
Electrostatic discharge IEC/EN61000-4-2 ±8KV/Contact±15KV/Air
Radiate susceptibility IEC/EN61000-4-3 10V/m
Electrical fast transient burst IEC/EN61000-4-4 ±2 KV
Surge IEC/EN61000-4-5 ±0.5 kV, ±1 kVL to N
Conducted susceptibility IEC/EN61000-4-6 10V(r.m.s)
Voltage dips and interruption IEC/EN61000-4-11 0%UT 0.5cycle at 0°,45°,90°,135°,180°,270°,315°
0%UT 1cycle70%UT 25/30 cycle0%UT 250/300 cycle