Products
- Video LCD Module
- Touch Panel
- TFT LCD Panel
- TFT LCD Panel
- T5L Evaluation Board
- Switching Power Supply
- LVDS LCD Module
- Linux LCD Module
- IoT Application
- HMI LCD Module
- HDMI LCD Module
- COF UART LCD Module
-
COB UART LCD Module
- 9.7 Inch
- 8.8 Inch
- 8 Inch
- 7.8 Inch
- 7.4 Inch
- 7 Inch
- 6.8 Inch
- 5.7 Inch
- 5.6 Inch
- 5 Inch
- 4.3 Inch
- 4.1 Inch
- 4 Inch
- 32 Inch
- 3.7 Inch
- 3.5 Inch
- 3 Inch
- 27 Inch
- 23.8 Inch
- 21.5 Inch
- 2.8 Inch
- 2.4 Inch
- 2.1 Inch
- 2 Inch
- 18.5 Inch
- 17.3 Inch
- 15.6 Inch
- 15 Inch
- 14 Inch
- 13.3 Inch
- 12.1 Inch
- 11.6 Inch
- 10.4 Inch
- 10.1 Inch
- 1.6 Inch
- 1.54 inch
- 1.3 Inch
- Android LCD Module
- Catalogue
72W 48V AC-DC Medical-grade Desktop Power Switching Adapter Model: ADA720K480S001B
Description
ADA720K480S001B is a desktop power adapter with a single output. With 100 -240 VAC universal input voltage, it can continuously output any DC voltage of 48VDC, 1M output cable length. Widely used in portable medical equipment .
Input Parameter
Voltage Range |
100~240 VAC, 180~370VDC |
Frequency Range |
47~63Hz |
Input Current (Max.) |
1.1A @ 100VAC, 0.6A @ 240VAC |
Efficiency (Typ.) |
88% |
Standby Consumption |
0.2W |
Impulse Current (Typ.) |
30A @ 100VAC, 40A @ 240VAC |
Leakage Current (Typ.) |
0.1mA @ 230VAC, 50Hz |
Output Parameter
Output Voltage |
48VDC |
Voltage Tolerance |
±5% |
Output Current |
1500mA |
Rated Power (Max.) |
72W |
Line Regulation |
±3% at full load |
Maximum Capacitive Load |
7000uF |
Load Regulation |
±3% |
Ripple & Noise |
150mV (Typ.), 200mV (Max.)@20MHz |
Frequency (Typ.) |
65kHz |
Hold up Time (Typ.) |
15mS @ 100VAC 80mS @ 240VAC |
Environment
Operating Temperature |
-40 ~ +70℃ |
Storage Temperature |
-40 ~ +85℃ |
Storage Humidity |
95%RH(Max.) |
Soldering Temperature |
250±10℃ @ Wave Soldering, 5~10s 360±10℃ @ Manual Soldering, 3-5s |
Protection Function
Short Circuit |
Long term short circuit, auto recovery. |
Over Current |
≥140%IO auto recovery |
Over Voltage |
≤55VDC @ 48V output |
IEC Safety Class |
CLASSII |
Electric Shock Protection |
2×MOPP @ primary to secondary |
Reliability
MTBF |
≥100,000H @ 25℃ |
Safety Standards / Directives
Medical Safety |
EN60601-1 |
|
CE |
Compliant |
|
Isolation Voltage (Min.) |
Input to Output |
4000VAC @ 1 minute test and the leakage current is smaller than 5mA. |
EMC
Parameter |
Standard |
Test Level / Note |
Conducted Emission |
EN55011(CISPR11) / EN55032(CISPR32) |
CLASS B |
Radiated Emission |
EN55011(CISPR11) / EN55032(CISPR32) |
CLASS B |
Voltage Fluctuation |
EN61000-3-2 |
- |
Harmonic Current |
EN61000-3-2 |
- |
Electrostatic Discharge |
IEC EN61000-4-2 |
±8KV/Contact ±2, 4, 8, 15KV/Air |
Radiate Susceptibility |
IEC EN61000-4-3 |
10V/m |
Electrical Fast Transient Burst |
IEC EN61000-4-4 |
±2 KV |
Surge |
IEC EN61000-4-5 |
±0.5/±1KV Professional/Family medicine |
Conducted Susceptibility |
IEC EN61000-4-6 |
3Vm/0.15MHz-80MHz 6Vm ( Within 15m band ) /0.15MHz-80MHz 80%AM,1kHz |
Voltage Dips and Interruption |
IEC EN61000-4-11 |
0%UT 0.5cycle 0°, 45°, 90°, 135°, 180°, 270°, 315°. 0%UT 1cycle 70%UT 25/30 cycle 0° 0%UT 250/300 cycle |
Mechanical Specification
Dimension |
126*50*30.3mm |
Enclosure Material |
Black flame retardant and heat resistant plastics(UL94V-0) |
Cooling Mode |
Natural air cooling |
Power and Cable Specification |
ul2464×20Awg*1m,5.5*2.5*straight head+magnetic ring+SR |