72W 48V AC-DC Medical-grade Desktop Power Switching Adapter Model: ADA720K480S001B

Features

  • Wide input voltage: the input working voltage range is 100-240VAC.
  • High energy efficiency: Six levels of energy consumption, power efficiency up to 88%.
  • High reliability: Compliant with EN60601-1, IEC CLASS Ⅱ and 2×MOPP insulation protection level, CE.
  • Flame retardant insulation: UL94V-0 flame retardant heat resistant material.
  • Full protections: Short Circuit/ Over Voltage/ Over Current/ Self-recovery.

    Description

    ADA720K480S001B is a desktop power adapter with a single output. With 100 -240 VAC universal input voltage, it can continuously output any DC voltage of 48VDC, 1M output cable length. Widely used in portable medical equipment .

    Input Parameter

    Voltage Range

    100~240 VAC, 180~370VDC

    Frequency Range

    47~63Hz

    Input Current (Max.)

    1.1A @ 100VAC, 0.6A @ 240VAC

    Efficiency (Typ.)

    88%

    Standby Consumption

    0.2W

    Impulse Current (Typ.)

    30A @ 100VAC, 40A @ 240VAC

    Leakage Current (Typ.)

    0.1mA @ 230VAC, 50Hz

    Output Parameter

    Output Voltage

    48VDC

    Voltage Tolerance

    ±5%

    Output Current

    1500mA

    Rated Power (Max.)

    72W

    Line Regulation

    ±3% at full load

    Maximum Capacitive Load

    7000uF

    Load Regulation

    ±3%

    Ripple & Noise

    150mV (Typ.), 200mV (Max.)@20MHz

    Frequency (Typ.)

    65kHz

    Hold up Time (Typ.)

    15mS @ 100VAC

    80mS @ 240VAC

    Environment

    Operating Temperature

    -40 ~ +70℃

    Storage Temperature

    -40 ~ +85℃

    Storage Humidity

    95%RH(Max.)

    Soldering Temperature

    250±10℃ @ Wave Soldering, 5~10s

    360±10℃ @ Manual Soldering, 3-5s

    Protection Function

    Short Circuit

    Long term short circuit, auto recovery.

    Over Current

    ≥140%IO auto recovery

    Over Voltage

    ≤55VDC @ 48V output

    IEC Safety Class

    CLASSII

    Electric Shock Protection

    2×MOPP @ primary to secondary

    Reliability

    MTBF

    ≥100,000H @ 25℃

    Safety Standards / Directives

    Medical Safety

    EN60601-1

    CE

    Compliant

    Isolation Voltage (Min.)

    Input to Output

    4000VAC @ 1 minute test and the leakage current is smaller than 5mA.

    EMC

    Parameter

    Standard

    Test Level / Note

    Conducted Emission

    EN55011(CISPR11)  / EN55032(CISPR32)

    CLASS B

    Radiated Emission

    EN55011(CISPR11)  / EN55032(CISPR32)

    CLASS B

    Voltage Fluctuation

    EN61000-3-2

    -

    Harmonic Current

    EN61000-3-2

    -

    Electrostatic Discharge

    IEC EN61000-4-2

    ±8KV/Contact

    ±2, 4, 8, 15KV/Air

    Radiate Susceptibility

    IEC EN61000-4-3

    10V/m

    Electrical Fast Transient Burst

    IEC EN61000-4-4

    ±2 KV

    Surge

    IEC EN61000-4-5

    ±0.5/±1KV

    Professional/Family medicine

    Conducted Susceptibility

    IEC EN61000-4-6

    3Vm/0.15MHz-80MHz

    6Vm ( Within 15m band )

    /0.15MHz-80MHz

    80%AM,1kHz

    Voltage Dips and Interruption

    IEC EN61000-4-11

    0%UT 0.5cycle

    0°, 45°, 90°, 135°, 180°, 270°,

    315°. 

    0%UT 1cycle

    70%UT 25/30 cycle 0°

    0%UT 250/300 cycle

    Mechanical Specification

    Dimension

    126*50*30.3mm

    Enclosure Material

    Black flame retardant and heat resistant plastics(UL94V-0)

    Cooling Mode

    Natural air cooling

    Power and Cable

    Specification

    ul2464×20Awg*1m,5.5*2.5*straight head+magnetic ring+SR

    ADA720K480S001B7.png